CT Primary Injection Testing Part 2

1

CT Primary Injection Testing Part 2, Mastering Current Transformer Primary Injection Testing.

Course Description

Welcome to the comprehensive online training on Current Transformer (CT) testing and verification. In this course, led by  an experienced Electrical Engineer with over 20 years of industry expertise, you will gain in-depth knowledge and practical insights into various aspects of CTs, including nameplate information, primary injection testing, verification points, circuit integrity, protection system functionality, and visual inspections.

This training program is designed to equip you with the necessary skills and knowledge to effectively test and verify current transformers. The course covers a wide range of topics, including understanding the nameplate information of CTs, addressing non-compliance between the CT nameplate and single line diagrams, importance of checking CT secondary test results, conducting primary injection tests, maintaining short circuit conditions in CT circuits, key verification points during primary injection testing, ensuring CT circuit integrity, validating protection system functionality, and conducting visual inspections and CT terminal tightening tests.

? What You Will Learn: By enrolling in this course, you will acquire the following skills and competencies:

  • Comprehensive understanding of CT nameplate information, including the total number of cores, protection and metering classes, available taps, rated thermal current, rated primary and secondary current, and applicable standards.
  • Techniques for addressing non-compliance issues between CT nameplates and single line diagrams during primary injection testing.
  • Importance of checking CT secondary test results and individual tests before conducting primary injection testing.
  • Recognizing scenarios that require the implementation of primary injection testing.
  • Understanding the significance of maintaining a short circuit condition in CT circuits to avoid open CT loops and ensure system safety.
  • Mastering the key verification points during primary injection testing, such as the sign convention for primary-side polarity in CTs, case studies on incorrect CT pole/phase polarity, CT ratio tests, relay/meter CT ratio data verification, phase verification, core verification tests, ensuring CT circuit integrity by detecting loose connections in the CT secondary circuit, and validating protection system functionality through final trip testing by primary injection.
  • Implementing essential precautions and safety measures when conducting CT primary injection testing.
  • Emphasizing the importance of gradually increasing current in primary current injection testing for safety, fault detection, equipment protection, and test validation.
  • Developing skills to conduct thorough visual inspections and CT terminal tightening tests to ensure optimal performance and reliability.

Embark on this training journey and gain the expertise required to effectively test and verify current transformers. Join us to enhance your knowledge and contribute to the safe and efficient operation of electrical systems.

Enroll now and unlock the world of CT.

Best Regards


We will be happy to hear your thoughts

Leave a reply

Online Courses
Logo
Register New Account
Compare items
  • Total (0)
Compare
0